When does GxP apply to my company? GLP, GCP and GMP explained
Last updated: 24 November 2026
Short answer: GxP becomes mandatory for your company as soon as you generate data or products that an authority relies on. That means GLP for non-clinical safety studies used in an application, GCP from planning and applying for a clinical trial, and GMP from the manufacture of investigational medicinal products. GxP is voluntary in pure research; if you outsource tasks to a CRO or CMO, responsibility stays with you as sponsor.
What does GxP mean, and what are GLP, GCP, GMP, GDP and GCLP?
GxP is the umbrella term for the “good practice” rules of medicines development. The “x” stands for the area concerned. A detailed introduction is available at What does GxP mean?.
- GLP (Good Laboratory Practice): quality system for non-clinical safety testing, such as toxicology. Directive 2004/10/EC requires Member States to ensure that test facilities comply with GLP principles (Art. 1) [1]. In the United States, 21 CFR Part 58 applies [20].
- GCP (Good Clinical Practice): ethical and scientific standard for clinical trials in humans. The EU legal basis is Regulation (EU) No 536/2014 (Clinical Trials Regulation, CTR), Art. 47 [3]. ICH E6(R3) sets out the detailed expectations [14].
- GMP (Good Manufacturing Practice): requirements for manufacturing and testing medicines. For medicines for human use, Directive (EU) 2017/1572 applies; it replaced Directive 2003/94/EC [5][6]. For investigational medicinal products, Delegated Regulation (EU) 2017/1569 applies [4]. The EU GMP Guide (EudraLex Volume 4) provides interpretation [6].
- GDP (Good Distribution Practice): requirements for storage and transport in wholesale distribution, laid down in the EU GDP Guidelines 2013/C 343/01 [12].
- GCLP (Good Clinical Laboratory Practice): guidance for laboratories analysing samples from clinical trials. It originates from the UK Research Quality Association (then BARQA) and was published by WHO/TDR in 2009 [22]. GCLP is industry guidance, not an EU legal act.
Which GxP rules apply to whom?
The rules that apply depend on your role, not on the size of your organisation. The table shows the typical EU allocation, with US rules added where they matter for small biotechs.
| Role | GLP | GCP | GMP | GDP |
|---|---|---|---|---|
| Manufacturer (authorised medicines) | – | – | Mandatory: manufacturing authorisation under Directive 2001/83/EC Art. 40; GMP under Directive (EU) 2017/1572 [2][5] | Wholesale of own products is covered by the manufacturing authorisation (Directive 2001/83/EC Art. 77(3)) [2] |
| Sponsor of a clinical trial | Non-clinical data in the application must comply with GLP (CTR Art. 25(3)) [3] | Mandatory: CTR Art. 47 and 71; ICH E6(R3) [3][14]; US: 21 CFR Part 312 [19] | Responsible for ensuring investigational products are made under GMP (ICH E6(R3) Annex 1, 3.15.2) [14] | Handling and shipping of investigational products under GCP and GMP (EudraLex guideline on sponsor responsibilities) [6] |
| CRO | Only for its own non-clinical testing | Mandatory for transferred tasks (CTR Art. 71; ICH E6(R3) 3.6.6; US: 21 CFR 312.52) [3][14][19] | – | – |
| Trial site | – | Mandatory for the investigator (CTR Art. 47; ICH E6(R3) Annex 1, section 2) [3][14] | Re-labelling or re-packaging in hospitals by pharmacists without a manufacturing authorisation, if the products are used only at sites in the same trial in the same Member State (CTR Art. 61(5)(a)) [3] | – |
| Non-clinical laboratory | Mandatory for regulatory safety studies (Directive 2004/10/EC Art. 1 and 2; US: 21 CFR 58.1) [1][20] | When analysing samples from clinical trials (ICH E6(R3) 3.11.3; GCLP as guidance) [14][22] | – | – |
| Wholesaler and distribution | – | – | – | Mandatory: wholesale distribution authorisation (Directive 2001/83/EC Art. 77); GDP Guidelines 2013/C 343/01 [2][12] |
| Contract manufacturer (CMO) | – | – | Mandatory: own manufacturing authorisation (CTR Art. 61; Directive 2001/83/EC Art. 40) and GMP (Delegated Regulation (EU) 2017/1569) [2][3][4] | – |
| Software vendor for regulated customers | No authorisation of its own. Requirements apply indirectly through contracts and audits: EU GMP Annex 11 section 3.1, EMA guideline on computerised systems (2023), ICH E6(R3) 3.6.6 [8][14][16] |
When does GxP start, and what does not yet apply in the research phase?
GxP is triggered by specific events. The main triggers for a small biotech are:
- First regulatory safety study (GLP): Non-clinical data in a clinical trial application must come from studies that comply with Union GLP principles (CTR Art. 25(3)) [3]. According to the European Commission’s CTR questions and answers (section 1), these studies take place in a test facility within a national GLP monitoring programme [18]. In practice, you commission a certified contract laboratory.
- Engaging a CRO or CMO: Your obligations as the contracting party start with the first contract. Tasks are transferred in writing (CTR Art. 71; ICH E6(R3) Annex 1, 3.6.1 and 3.6.4) [3][14]. For GMP activities, Chapter 7 of the EU GMP Guide requires a written contract with clearly allocated duties [7].
- Manufacture of investigational medicinal products (GMP): Manufacture and import of investigational products in the EU are “subject to the holding of an authorisation” (CTR Art. 61(1)) [3]. Delegated Regulation (EU) 2017/1569 sets out the GMP requirements [4]. If you do not manufacture yourself, your CMO must hold this authorisation.
- Clinical trial application (GCP): With the CTR application at the latest, you take on sponsor obligations. Sponsor and investigator ensure the trial runs “in accordance with the protocol and with the principles of good clinical practice” (Art. 47) [3]. From now on, you keep a trial master file (TMF) (Art. 57) and archive it “for at least 25 years after the end of the clinical trial” (Art. 58) [3].
- Own manufacturing authorisation (GMP): If you manufacture medicines yourself, you need an authorisation under Art. 40 of Directive 2001/83/EC and must comply with GMP under Directive (EU) 2017/1572 [2][5].
- Marketing authorisation application: All data in the dossier must have been generated under the applicable GxP rules. Authorities verify this through inspections of sponsors, CROs, trial sites and manufacturers.
What does not yet apply in the research phase: Basic research, target validation and exploratory pharmacology are not subject to GxP obligations. The FDA places “basic research” and “discovery toxicology studies” outside the GLP scope [21]. The European Commission also does not expect GLP compliance for exploratory non-clinical studies [18]. Traceable lab notebooks, controlled documents and clear data storage are voluntary but sensible. These data often feed into the investigator’s brochure later.
Who is liable when tasks are outsourced to a CRO or CMO?
Responsibility stays with the sponsor. This is the most important rule for small biotechs that outsource almost everything.
- EU law: A sponsor may delegate tasks to a CRO in a written contract. This is, however, “without prejudice to the responsibility of the sponsor”, in particular for participant safety and the reliability and robustness of the data (CTR Art. 71) [3]. The EMA confirms that the sponsor remains ultimately responsible when tasks are delegated [17].
- ICH E6(R3): The “ultimate responsibility” for transferred activities resides with the sponsor (Annex 1, 3.6.6). The sponsor selects and oversees service providers, including their subcontractors (3.6.7 to 3.6.9) [14].
- GMP outsourcing: Under Chapter 7 of the EU GMP Guide, the Contract Giver is “ultimately responsible” for controlling outsourced activities (7.4) [7]. The CMO also remains responsible for its own GMP compliance.
- United States: Under 21 CFR 312.52, transferred obligations are described in writing. The CRO is then “subject to the same regulatory action as a sponsor”. Obligations not transferred in writing remain with the sponsor [19].
Civil and criminal liability is governed by national and Union law; the CTR leaves it unaffected (Art. 95) [3]. In practice, contracts, quality agreements, supplier audits and documented oversight are your evidence for inspectors.
What does this mean for documentation, validation, audit trails and electronic signatures?
As soon as GxP-relevant data are created electronically, requirements apply to the systems used. The key points:
- Validation: The responsible party is accountable for the validation status throughout the life cycle, including systems developed by other parties (ICH E6(R3) Annex 1, 4.3.4) [14]. For GMP, EU GMP Annex 11 in its 2011 version applies [8].
- Audit trail: Audit trails must not be disabled (ICH E6(R3) 4.2.2) [14]. The EMA guideline on computerised systems and electronic data in clinical trials (EMA/INS/GCP/112288/2023) requires an audit trail for the creation and every modification of electronic data (section 6.2) [16].
- Electronic signatures: The EMA guideline requires authentication, non-repudiation, an unbreakable link to the record and a timestamp (section 4.8) [16]. For records under FDA regulations, 21 CFR Part 11 applies (§ 11.1) [23].
- Documentation and system inventory: The sponsor keeps a record of important computerised systems and their validation status (ICH E6(R3) 3.16.1 (x)) [14]. The EMA guideline explicitly covers eTMF systems [16].
For details, see our pages on 21 CFR Part 11 and electronic signatures, eDMS requirements for biotechs and CROs and eQMS requirements for clinical trials.
What is changing in 2025 and 2026?
Research date: 24 November 2026.
- ICH E6(R3), principles and Annex 1: ICH Step 4 on 6 January 2025; in effect in the EU since 23 July 2025 [13][15]. New elements include the risk-based approach and a dedicated section 4 on data governance [14]. For preparation, see ICH E6(R3) inspection readiness for sponsors.
- ICH E6(R3), Annex 2: Annex 2 on decentralised and pragmatic elements and real-world data reached Step 4 on 3 June 2026. The CHMP adopted it on 25 June 2026; it comes into effect in the EU on 15 January 2027 [13]. A consolidated version has been available since 16 June 2026 [14].
- EU GMP Annex 11 and Chapter 4 (draft): The European Commission and PIC/S consulted on drafts of a revised Annex 11 and Chapter 4 from 7 July to 7 October 2025 [9]. As of the research date, neither text has been adopted; EudraLex Volume 4 still lists the 2011 Annex 11 and Chapter 4 [6]. The work plan of the EMA GMP/GDP Inspectors Working Group targets Q4 2026 for handing final texts to the Commission [11]. No date of entry into force has been set.
- EU GMP Annex 22 Artificial Intelligence (draft): Annex 22 was consulted on as a new draft in the same procedure [9] and is not in force as of the research date. An EMA workshop on 30 June 2026 (report EMA/156789/2026) discussed widening the scope to adaptive and generative models [10]. The input will inform the ongoing revision [10].
- EMA guideline on computerised systems: Unchanged and in force. It was adopted on 7 March 2023 and, according to the EMA, has been in effect since 9 September 2023 [16].
How can small biotechs take a pragmatic approach?
Seed biotech before the first Phase I trial
- Commission GLP toxicology from a laboratory with a valid GLP certificate and check the certificate.
- Have the investigational product made by a CMO holding an authorisation under CTR Art. 61 and sign a quality agreement.
- Set up a lean quality management system: document control, training, supplier qualification, deviations and CAPA (corrective and preventive action). ICH E6(R3) requires risk-based quality management (Annex 1, 3.10) [14].
- Appoint a person responsible for quality assurance; an external solution is possible.
- Start the TMF with the first contract and choose a validated system with an audit trail for electronic filing.
Biotech with several trials
- Plan and document risk-based oversight of CROs (ICH E6(R3) 3.9) [14].
- Keep a system inventory, define an audit programme for service providers and check inspection readiness regularly.
- Connect eQMS and eTMF so that SOPs, training and trial documents stay consistent. For a market overview, see eQMS software compared 2026.
Small CRO
- Run your own QMS: ICH E6(R3) expects service providers to implement appropriate quality management and report relevant incidents to the sponsor (3.6.6) [14].
- List transferred obligations individually in every contract; for US trials, 21 CFR 312.52 requires this [19].
- Validate your own computerised systems and allow sponsor audits. The EMA guideline explicitly applies to service providers [16].
Frequently asked questions
Does GxP already apply in research?
No. Basic research and exploratory studies are not subject to GxP obligations [18][21]. Obligations start with regulatory safety studies, the manufacture of investigational products and the clinical trial.
Do I need an eQMS from the first trial?
The law does not prescribe a specific tool. The EMA states that sponsors are not required to use computerised systems [16]. Quality management, however, is mandatory (ICH E6(R3) 3.10) [14]. If you use an electronic system, it must be validated. Selection criteria are set out in eQMS for clinical trials.
What is the difference between GCP and GCLP?
GCP covers the whole clinical trial and is binding in the EU through CTR Art. 47 [3]. GCLP is guidance for laboratories analysing samples from clinical trials [22]. It complements GCP but has no legal status of its own in the EU.
Does GxP also apply to software vendors?
Not directly. The obligations fall on sponsors, investigators and manufacturers. They conclude formal agreements with vendors (EU GMP Annex 11, section 3.1) and qualify them [8]. The EMA guideline explicitly includes service providers [16].
Does a non-clinical laboratory need GLP certification?
For safety studies used in an application, yes: they take place in a test facility within the GLP monitoring programme [1][18]. For exploratory studies, no.
Does responsibility stay with the sponsor if the CRO takes over everything?
In the EU, yes (CTR Art. 71) [3]. In the United States, the CRO is additionally subject to regulatory action for obligations it has assumed in writing (21 CFR 312.52) [19].
Is the new Annex 11 already binding?
No. On 24 November 2026, the 2011 version applies; the revised Annex 11 and Annex 22 are drafts [6][9].
Docuply is an eQMS with an integrated eTMF for clinical biotechs and CROs. Hosting is in the EU. Plans are published at docuply.io/preise.
Sources
- Directive 2004/10/EC (Good Laboratory Practice): https://eur-lex.europa.eu/eli/dir/2004/10/oj/eng
- Directive 2001/83/EC (Community code relating to medicinal products for human use): https://eur-lex.europa.eu/eli/dir/2001/83/oj/eng
- Regulation (EU) No 536/2014 on clinical trials: https://eur-lex.europa.eu/eli/reg/2014/536/oj/eng
- Delegated Regulation (EU) 2017/1569 (GMP for investigational medicinal products): https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32017R1569
- Directive (EU) 2017/1572 (GMP for medicinal products for human use): https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32017L1572
- European Commission, EudraLex Volume 4 (GMP guidelines, overview): https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en
- EudraLex Volume 4, Chapter 7 Outsourced Activities: https://health.ec.europa.eu/document/download/58b5106a-cf6f-4352-9dca-1caf5d27d97e_en?filename=vol4-chap7_2012-06_en.pdf
- EudraLex Volume 4, Annex 11 Computerised Systems (2011): https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf
- European Commission, Stakeholders’ Consultation: Chapter 4, Annex 11 and New Annex 22: https://health.ec.europa.eu/consultations/stakeholders-consultation-eudralex-volume-4-good-manufacturing-practice-guidelines-chapter-4-annex_en
- EMA, Report: Multistakeholder workshop on AI guidance development (Annex 22), EMA/156789/2026: https://www.ema.europa.eu/en/documents/report/report-multistakeholder-workshop-expert-contributions-artificial-intelligence-guidance-development-annex-22_en.pdf
- EMA, 3-year work plan GMP/GDP Inspectors Working Group 2026–2028: https://www.ema.europa.eu/en/documents/other/3-year-work-plan-inspectors-working-group_en.pdf
- Guidelines on Good Distribution Practice of medicinal products for human use (2013/C 343/01): https://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ%3AC%3A2013%3A343%3A0001%3A0014%3AEN%3APDF
- EMA, ICH E6 Good clinical practice – Scientific guideline: https://www.ema.europa.eu/en/scientific-guidelines/ich-e6-good-clinical-practice
- EMA, ICH E6(R3) Guideline for Good Clinical Practice, Step 5 (EMA/CHMP/ICH/162879/2026): https://www.ema.europa.eu/en/documents/scientific-guideline/ich-e6r3-guideline-good-clinical-practice-step-5_en.pdf
- ICH, Efficacy Guidelines (E6): https://www.ich.org/page/efficacy-guidelines
- EMA, Guideline on computerised systems and electronic data in clinical trials (EMA/INS/GCP/112288/2023): https://www.ema.europa.eu/en/documents/regulatory-procedural-guideline/guideline-computerised-systems-electronic-data-clinical-trials_en.pdf
- EMA, Q&A: Good clinical practice (GCP): https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-clinical-practice/qa-good-clinical-practice-gcp
- European Commission, Regulation (EU) No 536/2014 Questions & Answers (EudraLex Volume 10): https://health.ec.europa.eu/document/download/bd165522-8acf-433a-9ab1-d7dceae58112_en
- eCFR, 21 CFR 312.52 Transfer of obligations to a contract research organization: https://www.ecfr.gov/current/title-21/chapter-I/subchapter-D/part-312/subpart-D/section-312.52
- GovInfo, 21 CFR Part 58 Good Laboratory Practice for Nonclinical Laboratory Studies: https://www.govinfo.gov/link/cfr/21/58?link-type=pdf§ionnum=3&volume=1&year=mostrecent
- FDA, Good Laboratory Practice (GLP), presentation: https://www.fda.gov/media/184296/download
- WHO/TDR, Good clinical laboratory practice (GCLP), 2009: https://tdr.who.int/publications/i/item/good-clinical-laboratory-practice-(-gclp)
- eCFR, 21 CFR Part 11 Electronic Records; Electronic Signatures: https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11
Author: Jan Krikava – A former life science consultant who founded Docuply on the back of his own consulting experience. 14 years of experience in quality management. Business Informatics B. Sc. LinkedIn: linkedin.com/in/jan-krikava